Questions?

 

93.20.410 - Tellarini enm 40 mess. 230v

Unit of Measure TypeSTUK
volt230 V
descriptionTellarini ENM 40
 
 
 
 
Robust self-priming side channel pump for clean liquids, gas oil, water, wine, fruit juice etc.

type: ECC, EEM, ENT and ENM
colour: blue with brass
pump type: self-priming liquid ring pump, not a centrifugal pump and may therefore NEVER be completely sealed off
impeller type: open star impeller
motor type: 12 and 24 volt : brush motor
: 230 volt : induction motor with reversing switch
: 400 volt : short circuit motor
rotation: 2 directions through reversing switch,only for 230 volt (EEM 20, EEM25, EEM 30 and ENM40)

fuse: NOT inbuilt
shaft seal: nitrile rubber lip seal with stainless steel spring, mechanical seal available and it can be fitted afterwards
materials: impeller : brass
: impeller housing : brass
: pump housing : brass
: pump shaft : stainless steel 316
liquids: maximum temperature 90°C continuous water, gas oil and other clean liquids without abrasive particles
insulation class: IP23 / IP44 / IP55

voltages: 12 V DC
: 24 V DC
: 230 V mains
: 400 V three phase

no head: 7,800 litres per hour
5 metres head: 6,300 litres per hour
10 metres head: 4,200 litres per hour
15 metres head: 2,220 litres per hour
discharge head: 19.0 metres maximum
suction head: 6.0 metres
particle size: zero
connections: 1.1/2" external thread and 1.1/2" hose connection
dimensions: lxwxh = 353 x 166 x 232 mm
weight: 14.7 kg
rotation: 2 directions through reversing switch,only for 230 volt (ENM 40)
insulation class: IP44 (ENM40) / IP55 (ENT40)

amperage: 230 V, 5.8 A
: 400 V, 2.1 A
shaft power: 0.9 kW, 1.2 hp, 1400 rpm